[3] Adjusting the channel level
Adjust so that the playback levels of the different channels are equal.
Make this adjustment by listening to the test tones output from the speakers at the listening position.
By factory default all the levels of all the channels are set to 0 dB.
This adjustment can also be made directly from the remote control unit. (CH SELECT Button)
1
If you are not at the system setting changing menu screen,
read step 1 and 2 on page 33.
2
At the system setting changing menu screen, use the
0
and
1 cursor buttons to select Channel Level Adjustment, then
press the ENTER button.
The channel level adjustment screen appears.
3
Use the
0
and
1 cursor buttons to
select Auto or Manual for the
Test Tone mode.
The selected setting is displayed
in yellow.
B Auto: Adjust the levels listening to test tones
automatically output from the different speakers.
B Manual: Select the speakers from which the test tones are
output when adjusting the levels.
Detailed settings can be made when this is set to
Manual first.
ENTER
Remote control unit Remote control unit
Remote control unit
4
When Yes is selected at Level Clear, the level settings
for all the speakers are set to 0 dB.
B Yes: The level settings for all the speakers are set to 0 dB.
B No: The currently set level settings are retained.
5
Adjust the channel levels in the test tone mode.
Use the
and ª cursor buttons to select the Test Tone
Start mode, then use the
0
cursor button to select Yes.
The test tone is output.
Use the MASTER VOLUME control on the main unit or the
VOLUME buttons on the remote control unit to adjust the
volume of the test tone to a level at which it is easy to
make this adjustment.
6
q When Auto is selected at Test Tone:
Test tones are automatically output from the speakers at
intervals of 4 seconds for two of the cycles shown below,
then at intervals of 2 seconds from the third cycle on.
Use the
0
and
1 cursor buttons to adjust the channel levels
so that the volume of the test tones output from the different
speakers sounds the same.
The level changes in units of 1 dB each time the
0
and
1
cursor button is pressed.
The level can be adjusted in the range 12 dB to +12 dB.
Front left Center Front right
Surround rightSurround left Subwoofer
w When Manual is selected at Test Tone:
Use the
and ª cursor buttons to select the speaker from
which the test tone is to be output, then use the
0
and
1
cursor buttons to adjust the channel levels so that the volume
of the test tones output from the different speakers sounds
the same.
The level changes in units of 1 dB each time the
0
and
1
cursor button is pressed.
The level can be adjusted in the range 12 dB to +12 dB.