Status request command (Host ! This unit) Status message (this unit ! host)
Request Command Ans. Command Remarks
Update
(for RCF400S
Update)
Update
(For unit
Update)
(For IP
Remote)
IP Remote
authentication
Update File ? @0?UF'\r' Update File ? OK @0UFOK'\r'
NG @0UFNG'\r'
Update start @0?UD'\r' Update Data xxxxx @0UDXXXXX'\r' XXXX:Update file information
NG @0UD'\r'
Update File data send
start
Update File
size:xxxxxxxx
@0?UTxxxxxxxx'\r' Update File transfer
start
OK @0UTOK'\r' for IP Remote
STOP mode only
NG @0UTNG'\r' NG is returned excluding STOP.
Password Login xx:User ID
yyyy:Password
@0?LIxx:yyyyyyyy'\r' Password Login OK @0LIOK'\r' for IP Remote
xx:User ID
xx=AD:Admin
NG @0LING'\r' for IP Remote
Other MAC Address @0?MA'\r' MAC Address XX.XXX (MB/S) @0MAXXXXXXXXXXXX'\r' XXXXX:MAC Address
NOTE
b is State :When Stop, it is possible to set.
b2 “Track No.” is a number of the playback order. The file is managed by “Track No.” in serial communications. “Track No.” is changed by “File Sort”.
b3 Preset is managed by not Preset Name but Preset No. (1-3) in serial communications.
b4 Character-code:ISO/IEC 8859-1