Denon M-1250 - Network Security Platform User Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
NIDAParadeTheatreTechSpecsJune14
This is a live document that is periodically updated. Always check with the venue for significant revisions.
Page 8 of 19
Box Booms 1 (PS & OP)
Setting Line to FOH Boom 11350mm 76°
Distances are to the highest downstage point of boom or perch.
Maximum lanterns per boom 6
Notes Access to these positions is via ladder and all climbers
must wear a harness and be attached to the fall arrest
device. Personnel must be trained in the use of this
equipment
Box Booms 2 (PS & OP)
Setting Line to FOH Boom 11679mm 66°
Distances are to the highest downstage point of boom or perch.
Maximum lanterns per boom 4
Maximum lanterns per boom 4
Notes Access to these positions is via ladder and all climbers
must wear a harness and be attached to the fall arrest
device.
Control:
Lighting desk Eos 4K Control Desk, Universal Fader Wing - 2x20
Net3 Radio Focus Remote (RFR) 2.4GHz
Control channels 4,000 Outputs/Parameters
Signal output interfaces • Ethernet (four ports) 802.3af compliant PoE
• ETCNet2
• Net3 (powered by ACN)
Signal distribution Three streams of DMX and Ethernet distribution
Net 3 Gateway
Dimmer Racks:
Total Dimmers 300
Dimmer Locations (10) 12 way Dimmers located on FOH Bridge
3.
(12) Dimmers located on OP Gallery. (1)
Dimmer located on the PS Gallery plus (2)
Dimmers can be placed where required.
2.4kW Dimmer Racks (10) State Automation APC Solution Cool 12
(digital)
(Front of House)
(15) Bytecraft APC Solution 12 (digital)
(Back of House)
Total dimmers @ 2.4kW per dimmer 300
Page view 7