- 1 - DENON AVR/AVC control protocol Ver. 3.18 Application model : AVR-3803(AVC-3570) From Serial Number XXX1512251 and up Application terminal : Se
- 10 - EVENT PARAMETER function example *RES. ZM ON MAIN-ZONE ON/OFF change ZMON<CR> OFF ZMOFF<CR> Z1 PHONO MU
- 11 - EVENT PARAMETER function example *RES. TP **(PRESET No.) TUNER PRESET change to No.** TPA1<CR> (PRESET No.”A1”)
- 2 - Protocol specification The following three data forms is defined. COMMAND : The message sent to a system(AVR/AVC) from a controller(Touc
- 3 - The example of a command * <CR> is the meaning of 0x0D. SIDVD<CR> : Select Input source DVD MSTHX SURROUND EX<CR>
- 4 - L) COMMAND and PARAMETER list COMMAND PARAMETER function example PW ON POWER ON/STANDBY change PWON<CR> STANDBY PW
- 5 - COMMAND PARAMETER function example CV SB UP ---SURROUND BACKch (SBch 1SP) CVSB UP<CR> SB DOWN CVSB DOWN<CR&
- 6 - COMMAND PARAMETER function example Z2 PHONO MULTI ZONE -2 mode set , and select source Z2PHONO<CR> | ---The name
- 7 - EVENT PARAMETER function example MS DIRECT SURROUND mode set MSDIRECT<CR> PURE DIRECT MSPURE DIRECT<CR>
- 8 - EVENT PARAMETER function example PS TONE DEFEAT ON PARAMETER setting PSTONE DEFEAT ON<CR> TONE DEFEAT OFF TONE DEFE
- 9 - EVENT(or RESPONSE) and PARAMETER list EVENT PARAMETER function example *RES. PW ON POWER ON/STANDBY change PWON<CR> STA