Specifications
RS-232C connector
This connector is used for an external controller.
b If you wish to control the POA-3012CI from
an external controller using the RS-232C
connector, perform the operation below
beforehand.
q Turn the POA-3012CI’s power.
w Turn off the POA-3012CI’s power from the
external controller.
e Check that the POA-3012CI is in the standby
mode.
Trigger output jack
The power of an external device equipped with
a trigger input jack can be turned on and off in
association with operations on the POA-3012CI.
Output level: 250 mA / 12 V
Check the trigger input conditions of the
connected device.
If the trigger input level of the connected device
is higher than 250 mA / 12 V and depending on
the short-circuiting conditions, the POA-3012CI’s
protection circuit may be activated, in which
case “TRIGGER OUT OVER LOAD” appears on
the display. If this happens, turn off the POA-
3012CI’s power and disconnect the connected
device.
External Controller
Master trigger input jack
The “POWER CONFIGURATION” setting is valid
at the time of a “MASTER TRIGGER”.
Voltage input to the MASTER TRIGGER input
terminal and operating status of the POA-3012CI:
At DC 3 ~ 30 V ···················· ON
At DC 0 V ···························· STANDBY
ZONE trigger input jack
The ZONE TRIGGER ON MODE setting is valid at
the time of a “TRIGGER IN”.
Voltage input to the TRIGGER IN input terminal
and operating status of the power amplifier of
each ZONE:
At DC 3 ~ 30 V ···················· ON
At DC 0 V ···························· STANDBY
Connections