deno_3_4641_2.pke
IP Link
®
Device Interface
Communication Sheet
Revision: 7/20/2011
Page 5 of 5
Cable and Adapter Requirements:
M/F RS-232 straight serial cable (Extron Electronics P/N 26-433-XX)
Notes for the Device:
By default, the Denon DVD Power Saving option is set to ON. This will prevent the Denon device to communicate
with control command when the device is on standby. In order to use the RS232 communication, you need to change
the Power Saving option to OFF. To disable the Power Saving option, the steps are as follows:
Setup Æ Custom Æ Other Æ Power Saving
Pin Assignments Diagram:
Note: Captive screw connector may also be used as a serial connection.
General Notes:
Serial communication:
Port Type:
RS-232 Parity:
Even
Baud Rate:
9600 Stop Bits:
1
Data Bits:
8 Flow Control:
None