EVENT PARAMETER
function example
Z3 PHONO ZONE3 source change Z3PHONO<CR>
| ---The name of PARAMETER is |
IPOD the same as that of the time of SI COMMAND. Z3IPOD<CR>
SOURCE ZONE3 mode cancel Z3SOURCE<CR>
** ZONE3 VOLUME change , **:10 to 99 by ASCII Z380<CR>
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
99 = ---(MIN)
ON ZONE3 ON/OFF change Z3ON<CR>
OFF Z3OFF<CR>
Z3MU ON ZONE3 OUTPUT MUTE ON/OFF change Z3MUON<CR>
OFF Z3MUOFF<CR>
Z3CS ST ZONE3 Channel setting Z3CSST<CR>
MONO Z3CSMONO<CR>
Z3CV FL ** **:38 to 62 by ASCII , 50=0dB Z3CVFL 50<CR>
FR ** **:38 to 62 by ASCII , 50=0dB Z3CVFR 50<CR>
Z3HPF ON ZONE3 HPF ON/OFF change Z3HPFON<CR>
OFF Z3HPFOFF<CR>
Z3PS BAS ** ZONE3 BASS change Z3PSBAS 00<CR>
TRE ** ZONE3 TEBLE change Z3PSTRE 00<CR>
Z4 CD ZONE4 source change Z4CD<CR>
| ---The name of PARAMETER is |
V.AUX the same as that of the time of SI COMMAND Z4V.AUX<CR>
that is assigned DIGITAL INPUT.
SOURCE ZONE4 mode cancel Z4SOURCE<CR>
ON ZONE4 ON/OFF change Z4ON<CR>
OFF Z4OFF<CR>
The PARAMETER of Z3 EVENT : Uses two ASCII characters. (see page 6 J) section)