Denon D-AJ03 Service Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 53
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
12
12
D-AJ03
No
No
No
No
No
No
TROUBLESHOOTING OF CD
CD SECTION
When the CD does not function
When the CD section does not operate when the objective lens of the optical pickup is dirty, this section may not operate.
Clean the objective lens, and check the playback operation. When this section does not operate even after the above step
is taken, check the following items.
Remove the cabinet and follow the trouble shooting instructions.
“Track skipping and/or no TOC (Table of Contents) may be caused by build up of dust other foreign matter on the laser
pickup lens. Before attempting any adjustment make certain that the lens is clean. If not, clean it as mentioned below.”
Turn off the power, and wipe the lens softly using a cleaning paper moistened with commercially available cleaning solution
so as not to damage it.
Be careful not to touch the lens with bare hands.
Dust gradually accumulates on the objective lens during use, and it may degrade performance. To avoid this problem, use
a cleaning disc designed for CD optical pickup lenses.
Does the unit switch from the CD test mode 1 to 2 ?
When the CD test mode is changed from 2 to 3, does the
disc motor rotate properly ?
Refer to "The disc motor CLV servo is defective".
Yes
Yes
Yes
When a disc is loaded, the power is turned on, and the CD (stop) button is pressed, is +7.2V applied to the collector of TR102 and +5.0V to
the emitter ? Is +3.3V applied to pin 22 on IC145 ?
Is the output at pin 19(HF) of IC146 flat in the CD test mode 4 ?
Refer to "HF is abnormal".
Is sound output when the pickup lens is moved to where a
track is located by pressing the
(button) and (button)
in the CD test mode 5 ?
Does the sled motor run ?
Yes
Yes
Are tracks played from the track 1 in ascending order by
pressing the
(button) ?
Yes
No
Refer to "The sled motor
does not run".
No
Refer to "No sound is heard".
Yes
When the unit is turned off and on again, is it initialized ?
Has the optical pickup
returned to the inner
periphery position ?
Yes
Yes
No
Is the optical pickup in
switch in the OFF state ?
The optical pickup in-switch
is defective (ON state).
Check the
microcomputer
PWB.
The optical
pickup in
switch is
defective.
OFF
ON
Refer to "Track search is impossible".
Normal
Yes
Is the voltage applied as shown in the wiring diagram ?
Check the power circuit in the main unit.
Is the laser lit in the CD test mode 1 ?
Refer to "The laser does not light up".
Refer to "Out of focus".
No
http://www.xiaoyu163.com
http://www.xiaoyu163.com
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 52 53

Comments to this Manuals

No comments