CONFIRMING THE SERVO
What is Service Program
Service program is a special program intended for confirming servo functions etc.
Required Measuring Implement
Reference disc (TCD784 or CO-74176)
1. Contents of Service Program
Turn on the power while pressing both B button and the PARAMETER knob to set the service mode of DN-S3500. The various
check items can be selected with the PARAMETER knob, the various test items can be selected with the A, SAMP, EXIT/RELOOP,
(SAMP.)EXIT/RELOOP, and BEND buttons. Press either the PARAMETER knob or PLAY/PAUSE button to start the check
or test and display the result.
To eject the disc, press the DISC EJECT button.
To cancel the service mode, turn the power off.
Process No.
(TRACK
Indication)
Function
(Character-display)
Contents
PARAMETER
knob
01
µcom Version check
(Version No.)
A PARAMETER knob is pushed and a version is checked.
1. System µcom version No. : "System_XXXX"
2. DSP soft version No. : "Dsp_XXXX"
02
"TR_Signal"
"HF_Signal"
Press the PARAMETER knob to turn the tracking servo off.
When the tracking servo is off, press the PARAMETER knob to turn the tracking
servo on.
03
Automatic Servo
Adjustment call
(Servo Data)
Press the PARAMETER knob to start automatic servo adjustment. When the
adjustment is completed, the adjustment data is displayed. The data can be
selected by turning the EFFECTS knob.
1. Disc check, CD/CD-RW
2. Focus gain data
3. Focus balance data
4. Focus offset data
5. Tracking gain data
6. Tracking balance data
7. Tracking offset data
8. S curve maximum
9. S curve minimum
04 "Fo_Gain"
Select the focus gain. Default : 7. Select the data with the scratch disc, then press
the PARAMETER knob to enter it. The higher the value, the higher the gain, while
the lower the value, the lower the gain.
* Do not change this without instruction from engineering.
05 "Tr_Gain" Select the tracking gain. Default : 2. The operation is the same as for the Fo Gain.
06 "Block_Err" The block error rate is displayed.
07 "PU._Clean"
When the PARAMETER knob is pressed, the pickup moves towards the outer
edge of the disc. The pickup lens becomes visible through the slit in the CD mech-
anism plate. The lens can be cleaned using a cotton swab, etc.
(Perform this operation with the top panel/cover removed and the disc ejected.)
08
Error Code Check
(Error Data)
During normal operation, the error code for the error that occurred is displayed.
Turn the EFFECTS knob to select up to 10 sets of error data stored in the mem-
ory. (See the error code table for a description of the error codes.)
Press the PARAMETER knob to set the error data clear mode. ("Error Clear?" is
displayed.) Press the PARAMETER knob again to clear all the error data.
09
Total Running Time
(Total Time)
The total operating time of the spindle motor is displayed. A total of 65,535 hours
can be counted, in units of hours.
NOTE: If the power is turned off after 59 minutes or less, that hour is not counted.
Press the PARAMETER knob to set the total time clear mode. ("Time Clear?" is
displayed.) Press the PARAMETER knob again to clear the total time.
サービスモード
サービスモードについて
サービスモードは、サーボ状態などを確認するための特別なプログラムです。
確認に必要な測定器具
リファレンスディスク:TCD784、CO-74176
1. サービス プログラムの内容
DN-S3500 は B ボタンとパラメータノブを両方押しながら、電源を投入するとサービスモードになります。パラメータノブで各チェック項目が、A ボタン、
SAMP ボタン、EXIT/RELOOP ボタン、(SAMP.)EXIT/RELOOP ボタン、 ボタンまたは BEND ボタンで各テスト項目が選択できます。
パラメータノブを押すか、PLAY/PAUSE ボタンを押すと各項目のチェック、テストを開始し、その結果を表示します。
ディスクをイジェクトするには、DISC EJECT ボタンを押します。
サービスモードをキャンセルするには、電源を切ってください。
チェック項 No.
( トラック番号 )
機能
キャラクター表示
内容
パラメータノブ
01
マイコンバージョンチェツク
Version No
パラメータノブを押して、バージョンをチェックします。
1.システムマイコンバージョン No.:"System_XXXX"
2.DSP ソフトバージョン No.:"Dsp_XXXX"
02
"TR_Signal"
"HF_Signal"
パラメータノブを押すとトラッキングサーボを off します。
トラッキングサーボ off のとき、パラメータノブを押すとトラッキングサーボを on します。
03
サーボ自動調整値
読み出し
(Servo Data)
パラメータノブを押すとサーボ自動調整を開始します。調整が終了すると、調整データ表示
します。データはエフェクトノブを回すことで選択できます。
1. ディスクチェック、CD/CD-RW
2. フォーカス ゲイン データ
3. フォーカス バランス データ
4. フォーカス オフセット データ
5. トラッキング ゲイン データ
6. トラッキング バランス データ
7. トラッキング オフセット データ
8. S カーブ最大値
9. S カーブ最小値
04 "Fo_Gain"
フォーカスゲインを選択します。デフォルト -7。スクラッチディスクでデータを選択し、パラメータノブを押
すと確定されます。数値が大きくなるとゲインが高くなり、数値が小さくなるとゲイン
が低くなります。
*設計からの指示がない限り変更しないで下さい。
05 "Tr_Gain" トラッキングゲインを選択します。デフォルト -2.操作方法は Fo Gain と同じ。
06 "Block_Err" ブロックエラーレートが表示されます。
07 "PU._Clean"
パラメータノブを押すとピックアップがディスク外周方向へ移動します。CD メカ板金の隙間か
ピックアップのレンズが見えるようになります。綿棒等でレンズをクリーニングすることができ
ます。
( トップパネル / カバーを外し、ディスクをイジェクトした状態で実施下さい )
08
エラーコードチェック
(Error Data)
通常動作時、発生したエラーのエラーコードが表示されます。エフェクトノブを回すと、大 10
個まで、記憶されたエラーデータが選択できます。( エラーコードはエラーコード表を参照下さい。)
・パラメータノブを押すと、エラーデータ消去モードにります。(Error Clear?が表示れま
す ) 再度、パラメータノブを押すと、全てのエラーデータが消去されます。
09
トータルランニングタイム
(Total Time)
スピンドルモータのトータル動作時間を表示します。1 時間単位で 65535 時間まで計測でき
ます。注意 )59 分以下で電源を切るとカウントされません。
パラメータノブを押すと、トータル時間消去モードになります。(Time Clear?が表示されま
す ) 再度、パラメータノブを押すと、トータル時間が消去されます。
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 59 60

Comments to this Manuals

No comments