1-5 Setting the MIC Input Select
1
Select Mic Input Select at the Auto Setup / Room EQ Menu.
(Remote control unit)
Mic In Select
*AutoSet/RoomEQ
Use this setting when using a microphone other than the included one for measurements when performing the auto setup procedure.
The microphone included with the AVR-2805 is a measurement microphone designed specifically for use during the auto setup procedure.
Select Mic and connect the included microphone to the SETUP MIC mini-jack. When conducting the auto setup procedure using a separate
high performance condenser microphone for measurements, select V.AUX L and connect the microphone to the V.AUX Lch pin jack.
Please ask the DENON Authorized Service Center about the usable microphone other than the option setup.
2
Display the Mic Input Select screen.
(Remote control unit)
3
Select the Mic input jack or V.AUX L jack.
(Remote control unit)
4
Enter the setting.
The Auto Setup / Room EQ Menu reappears.
(Remote control unit)
1-6 Check the EQ parameter
1
Select EQ Parameter Check at the Auto Setup / Room EQ
Menu.
(Remote control unit)
The frequency characteristic of each speaker is rectified and the tone of the speaker is unified.
The EQ parameters that were set in Auto Setup can be checked.
This item is automatically displayed, after the measurement result of the Auto Setup / Room EQ is decided.
2
Display the EQ Parameter Check screen.
(Remote control unit)
Mic
*Mic In Select
Parameter Check
*AutoSet/RoomEQ
1:Normal
*ParameterCheck