15
4. CONTROL FEATURES
RS232C CONTROL
Connect the RS-232C straight cable to the RS-232C serial port (D-sub 9-pin). Then the unit can
be controlled from external host equipment.
• The DN-F400 automatically transmits status data when status is changed.
• The DN-F400 will respond to status requests by transmitting the associated status data
RS232C specifications.
Connections
• Applicable connector : 9-pin D-sub (male)
• Baud rate : 38400 bps
• Data Bit : 8bit
• Parity : None
• Stop bit : 1bit
• Flow control : None
Pin layout
Pin No Signal Name
1 Ground
6NC
2 TxD
7NC
3 RxD
8NC
4NC
9NC
5 S. Ground
Control command codes
The control command packets have a data length of 7 bytes or more. Each packet starts with
“@” and ends with 0x0D.
Example: Control command code for number 5 (ASCII code @02005CR)
@02005CR
0x40 0x30 0x32 0x30 0x30 0x35 0x0d
Response timeout is 100 mSec.
Status Request and Status Information codes
Example: Status Information code “Disc In” (ASCII code @0 CDCI CR)
@0CDC ICR
0x40 0x30 0x43 0x44 0x43 0x49 0x0d