4.CONTROL FEATURES
PARALLEL CONTROL
Connections
The settings of Pins No. 16 to 20 can be changed with switch No. 6 PARALLEL of the MODE
switch on the rear panel of the DN-F400. (See page 11)
Pin No. Signal Name
I/O
1 Hot Start 1 I
2 Hot Start 2 I
3 Hot Start 3 I
4 Hot Start 4 I
5 Hot Start 5 I
6 Hot Start 6 I
7 Hot Start 7 I
8 Hot Start 8 I
9 Hot Start 9 I
10 Hot Start 10 I
11 Hot Start 11 I
12 Hot Start 12 I
13 Hot Start 13 I
14 Hot Start 14 I
15 Hot Start 15 I
16 Hot Start 16 I
17 Hot Start 17 I
18 Hot Start 18 I
19 Hot Start 19 I
20 Hot Start 20 I
21 PLAY I
22 STOP I
23 Command Common -
24 PLAY Tally O
25 Tally Power supply -
Pin No. Signal Name
I/O
1 Hot Start 1 I
2 Hot Start 2 I
3 Hot Start 3 I
4 Hot Start 4 I
5 Hot Start 5 I
6 Hot Start 6 I
7 Hot Start 7 I
8 Hot Start 8 I
9 Hot Start 9 I
10 Hot Start 10 I
11 Hot Start 11 I
12 Hot Start 12 I
13 Hot Start 13 I
14 Hot Start 14 I
15 Hot Start 15 I
16 Track Jump + I
17 Track Jump - I
18 FWD I
19 RWD I
20 PAUSE I
21 PLAY I
22 STOP I
23 Command Common -
24 PLAY Tally O
25 Tally Power supply -
• Switch No.6:
Set to ON (Hot start mode).
• Switch No.6:
Set to OFF (Normal mode).
Note:
The tally output pin has open collector IC specifications (Imax. 10mA, Vmax. 5.5V).
The tally input pin has LVTTL IC specifications (Vcc 3.3V).
Maximum current for Tally power supply (Pin 25) is 100mA.
Remote control circuit
• Remote control connections (Normal mode)
24
21
23
25
23
20
18
23
22
19
23
16
23
17
23
2
23
3
23
4
23
5
23
6
23
7
23
8
23
1
23
10
23
11
23
12
23
13
23
14
23
15
23
9
23
1
2
3
4
5
6
7
8
9
11
10
12
13
14
15
16
17
18
19
20
21
24
25
22
23
23
TRACK (–) TRACK (+) 1 SEARCH ¡ PAUSE PLAY
STOP
HOT START1 HOT START2 HOT START3 HOT START4 HOT START5 HOT START6 HOT START7 HOT START8
HOT START9 HOT START10 HOT START11 HOT START12 HOT START13 HOT START14
HOT START15
Note:
The rating of REMOTE connector pin 25 (TALLY POWER SUPPLY) is +5 VDC, 100 mA
maximum.
Avoid currents in excess of the rating, or it may cause a malfunction or a risk of fire.