Denon AVR 3806 - AV Receiver Operations Instructions Page 77

  • Download
  • Add to my manuals
  • Print
  • Page
    / 142
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 76
72
Advanced Setup – Part 1 Advanced Setup – Part 1
Setting the Power Amplifier Assignment
If no Surround back speakers are used in the main room, their
amplifier channels can be assigned for multizone use or the
front speakers bi-amp connection.
1
Press the CURSOR
DD
or
HH
button to select the
“Power Amp Assign” at the “Option Setup”
menu, then press the ENTER button.
The Power Amp Assign screen appears.
2
Press the CURSOR
FF
or
GG
button to select which
channel to assign the surround back power
amplifier to.
S. Back:
The Surround back speakers are used in MAIN ZONE.
Front:
This provides a bi-amp mode for the two main front
speakers, replicating the front left and front right
amplifier channels outputs.
Front B:
Both surround back power amplifier channels can be
used to provide a second set of stereo outputs that
match the front left and right speakers, providing a
Speaker B option for stereo sound in another location
( page 69).
ZONE2:
This mode assigns the surround back amplifier channels
to provide ZONE2 speaker-level outputs from the
surround back speaker terminals.
ZONE3:
This mode assigns the surround back amplifier channels
to provide ZONE3 speaker-level outputs from the
surround back speaker terminals.
3
Press the ENTER button to enter the setting.
The Option Setup menu reappears.
Setting the Volume Control
Set the upper limit for the volume, the volume level when the
power is turned on, and the volume level when the mute mode
is set for the different zones.
1
Press the CURSOR
DD
or
HH
button to select the
“Volume Control” at the “Option Setup” menu,
then press the ENTER button.
The Volume Control screen appears.
2
Press the CURSOR
DD
or
HH
button to select the
desired setting, then press the CURSOR
FF
or
GG
button to select the parameter.
Volume Limit:
Set the upper limit for the volume for the different zones.
20 dB, 10 dB, 0 dB:
The volume cannot be increased above the selected
levels.
OFF:
If you do not want to set a volume limit, select OFF.
In this case, the volume can be set to the AVR-3806s
maximum volume (output) level of +18 dB, which is
extremely loud.
Power On Level:
Set the volume that is set when the power is turned on
for the different zones.
You can adjust the MAIN ZONE volume level within the
range of 80 to +18 dB in steps of 1.0 dB and the ZONE2
(or ZONE3) volume level within the range of 70 dB to
+18 dB in steps of 1.0 dB.
(Mute)
The volume is always muted when the power is turned
on.
LAST
The volume set when the AVR-3806 was last used is
stored in the memory and set when the power is turned
on.
Front Bi-Amp connections
Certain loudspeakers are equipped with two sets of input
terminals, for bi-amplification. The AVR-3806 Amp Assign
mode allows you to power bi-amp-capable speakers with
two amplifier channels. Be sure to consult the owners
manual of your bi-amp-capable speakers for further
information before proceeding.
AVR-3806
SPEAKER
NOTE:
When making bi-amp connections, be sure to remove
the short-circuiting bar included with the speaker.