Part Names and Functions
Front Panel
q Power operation button (ON/STANDBY) ···························· (13)
w Power indicator ······································································ (13)
e Power switch (hON jOFF) ················································· (13)
r Left channel meter select button (METER) ·························· (13)
t Left channel meter indicators (L1 / L2 / L3 / L4) ················· (13)
y Left channel level meter ························································ (13)
u Center channel meter indicators (L5 / R5) ··························· (13)
i PRE AMP CONTROL LINK indicator ········································ (6)
o Center channel meter select button (METER) ····················· (13)
Q0 Center channel level meter ··················································· (13)
Q1 Right channel meter select buttons (METER) ····················· (13)
Q2 Right channel meter indicators (R1 / R2 / R3 / R4) ············· (13)
Q3 Right channel level meter ······················································ (13)
Q4 METER ON/OFF button ························································· (13)
NOTE
When outputting a program source that has data such as SACD, which
is higher than the audible band, the indicator moves differently than
the volume you hear.
n
About channel level meter
You can select the output level (dB indicator) of each power amp
channel to check the meter.
If a sine wave is input, the output power for the meter indicator is
as shown in the following table.
When NORMAL connection or Bi-AMP connection is used
Output
indicator
4 Ω/ohms load 6 Ω/ohms load 8 Ω/ohms load
0 (dB) 300 (W) 200 (W) 150 (W)
–10 (dB) 30 (W) 20 (W) 15 (W)
–20 (dB) 3 (W) 2 (W) 1.5 (W)
–30 (dB) 300 (mW) 200 (mW) 150 (mW)
–40 (dB) 30 (mW) 20 (mW) 15 (mW)
–50 (dB) 3 (mW) 2 (mW) 1.5 (mW)
When BRIDGE connection is used
Output
indicator
4 Ω/ohms load 6 Ω/ohms load 8 Ω/ohms load
0 (dB) 1200 (W) b 800 (W) b 600 (W) b
–10 (dB) 120 (W) 80 (W) 60 (W)
–20 (dB) 12 (W) 8 (W) 6 (W)
–30 (dB) 1200 (mW) 800 (mW) 600 (mW)
–40 (dB) 120 (mW) 80 (mW) 60 (mW)
–50 (dB) 12 (mW) 8 (mW) 6 (mW)
b Possible output by POA-A1HDCI is up to the rated output.