Denon AVR 4806 - AV Receiver Operations Instructions Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 154
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
25
Easy Setup and Operation
MeasuresCauseScreen example
About the error message
These error messages will be displayed when performing the measurements of Auto Setup and the automatic measurements
can not be completed because of the speaker arrangement, measurement environment, or other factors. Please check the
following matters, reset the pertinent items, and measure again. Be sure to turn off the AVR-4806’s power before checking the
speaker connections.
q The speakers required for producing suitable
reproduction have not been detected.
The front L and front R speakers were not
properly detected.
Only one channel of the surround (A) and
surround (B) speakers was detected.
Sound was output from the R channel when
only one surround back speaker was
connected.
The surround back or the surround (B) speaker
was detected, but the surround (A) speaker
was not detected.
If multiple errors occur, press the CURSOR
FF
or
GG
button to check the contents.
Check that the pertinent speakers
are properly connected.
w The speaker polarity is connected in reverse.
If multiple errors occur, press the CURSOR
FF
or
GG
button to check the contents.
Check the polarity of the pertinent
speakers.
For some speakers, the screen
below may be displayed even though
the speakers are properly connected.
If so, select “Skip
0
”.
e There is too much ambient noise in the room
and the measurements cannot be made
accurately.
r The sound level that is output from the
speakers and/or subwoofer is too low.
Either turn off the power of the
device that generated the noise
during the measurements or move
the device away.
•Try again at a time when it is quieter.
Check the placement and orientation
of the loudspeakers.
Adjust the subwoofer’s output level.
t The measurement microphone is not
connected, or all of speakers have not been
detected.
•Connect the measurement microphone
to the microphone connector.
Check the speaker connection.
Playing a DVD with Surround Sound
1
Disconnect the microphone from the unit.
2
Select the input source to be played.
3
Select the play mode.
4
5
Adjust the volume.
Start DVD playback.
Page view 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 153 154

Comments to this Manuals

No comments