F Menu screen F
2.Manual Setup
2.HDMI Setup
1.Speaker Setup
4.ZONE2 Setup
5.Option Setup
3.Audio Setup
Option Setup
Make various other settings.
a
Amp Assign
Define how the amplifier for the surround back speaker channels
is used.
The places where the surround back amplifier are used can be set
freely according to the usage environment. This makes it possible to
output sound to rooms other than the room (the MAIN ZONE) where
surround playback is performed (multi-zone playback) or play the sound
with high quality using the front speakers (bi-amp connections).
[Selectable items]
7.1ch
: The surround back channel is output from the
speakers connected to the SURR.BACK/AMP
ASSIGN terminals.
ZONE2
: When ZONE2 power is on, ZONE2 sound is
emitted from the speaker connected to the SURR.
BACK/AMP ASSIGN terminal.
FrontA Bi-Amp
: The Front A channel for Bi-Amp use is output from
the speakers connected to the SURR.BACK/AMP
ASSIGN terminals.
FrontB Bi-Amp
: The Front B channel for Bi-Amp use is output from
the speakers connected to the SURR.BACK/AMP
ASSIGN terminals.
For details, see “Amp Assign / Multi-zone Connections and Operations”
(vpage 60 ~ 62).
2.Vol.Control
3.Source Delete
4.On-Screen Display
5.Quick Select Name
6.Remote ID Setup
7.Display
8.Setup Lock
1.Amp Assign
2-5.Option Setup
s
Volume Control
Set the MAIN ZONE volume setting.
Volume Limit
Make a setting for maximum volume.
[Selectable items]
OFF
: Do not set a maximum volume.
–20dB
: Set the maximum volume to –20 dB.
–10dB
: Set the maximum volume to –10 dB.
0dB
: Set the maximum volume to 0 dB.
Power On Level
This sets the volume set when the MAIN ZONE’s power is turned
on.
[Selectable items]
Last
: Use the memorized setting from the last session.
– – –
: Always use the muting on condition when power
is turned on.
[Variable range]
–80dB ~ +18dB
: Set the volume level when the power is turned on
in units of 1 dB.
Mute Level
This sets the amount of attenuation of the volume when the mute
mode is set in the MAIN ZONE.
[Selectable items]
Full
: The sound is cut off entirely.
–40dB
: The sound is attenuated by 40 dB.
–20dB
: The sound is attenuated by 20 dB.
d
Source Delete
Remove input sources that are not used from the display.
[Selectable items]
ON
: Use this source.
Delete
: Do not use this source.
f
On-Screen Display
Make on-screen display related settings.
See page 8 for more information on onscreen displays due to
input signals.
NOTE
Input sources being used in the various zones cannot be deleted.
Input sources set to “Delete” cannot be selected using SOURCE
SELECT.
Text
Input source and mode display.
[Selectable items]
ON
: Turn display on.
OFF
: Turn display off.
Screensaver
Make screensaver settings.
Use the screensaver to prevent burn-in on the monitor screen.
When set to “ON”, the screensaver is activated if there is no activity
for about 3 minutes.
[Selectable items]
ON
: Activate the screensaver if there is no activity for about 3
minutes.
OFF
: Turn the screensaver function off.
Default
Reset the settings to the default values.
Setup
When “Screensaver” is set to “ON” , the screensaver is activated if
no operation is performed for about 3 minutes.
When you press uio p, the screen saver is cancelled and the
screen before that screen saver started is displayed.